Thursday, February 27, 2014

New auto shutoff timer switch for attic fan

new auto shut-off timer switch (for attic fan)


When I installed my attic fan several months ago, I also incorporated in a standard 2-way toggle switch to ensure the fan doesn't run unless I want it to. Yesterday, I decided to change out the toggle switch with this auto shut-off timer switch: http://www.intermatic.com/?action=subcatsid=46 When I was using my toggle switch, I had the black, white, and ground wires connected to it. With the new timer switch, there isn't a terminal screw for the ground wire. So, I just left the ground wire dangling in the box. Should I be concerned? (The new timer switch works fine.) Though I usually hate the word dangling, you are fine. Not all devices like switches have grounding screws and are either grounded through the frame or are all-plastic and have no need for grounding (like many smoke detectors.) Edit: Does that have a metal coverplate? Is your junction box metal (and grounded) or plastic? Heh heh--the ground wire is actually folded and tucked in pretty tight because there's not much space left in the j-box. Regarding your questions: Yes, the timer has a metal coverplate. My j-box is plastic. Thanks again for your response--I really appreciate it. You need a metal box. At the very least, ground the metal switch plate. But you really need a metal box. Originally Posted by racraft You need a metal box. At the very least, ground the metal switch plate. But you really need a metal box. Just installed the metal box last weekend--thanks again for the tips. I actually have one more question: The drywall hole for the existing box was oriented horizontally, and now I'd like to reorient the new box so that it sits vertically. What's the best way to do this? (Is there a trick or technique for recutting the existing horizontal drywall hole, or would I be better off cutting a new vertical hole at a different location, and completely patching the old hole?) Bob, If the metallic cover was connected to the ground wire from within the box, via the cover screw, do you feel a metallic box is needed? Without the metal box, it seems that compliance with 314.25(A) and 250.110 are complied with.


Related Posts:




  • Need to replace intermatic e1020 timer switch whats it do good replacement

    Need to replace Intermatic e1020 timer switch. What's it do? Good replacement?We moved into our house five years ago and noticed an Intermatic e1020 on the laundry room wall. Over the years it has...


  • Programable timer switch with dimmer

    Programable Timer Switch with DimmerI would like to instal a programable timer wall switch that also has a dimmer capability. Does such a product exist? Originally Posted by Thomas62 I would like...


  • Pool pump timer recommendations

    Pool Pump Timer Recommendations?I'd like to setup my pump on a timer. The only one that I've found in the big-box retailers (i.e. Lowes and Home Depot) is one from Intermatic. But this only suppor...


  • Open limit switch on goodman furnace

    Open limit switch on Goodman furnaceI have a goodman GMT045-3B furnace that I've had lots of issues with. The latest is a problem when I turn the heat on. The flame ignites, but the blower will no...


  • No heat continuous blower aux limit switch

    No heat, continuous blower (aux limit switch?)Hi, This morning our furnace blower is operating continuously, but with no heat, and a flashing code on the electronic controller's LED: York Diamond...