Air Filter Panel Cover on Bryant Gas Furnace?
Bought the house recently. And have noticed there is no sort of covering over where the side panel air filter goes. Please see image. Doesn't seem like it loses too much air out of here, but I assume putting a cover on this could make it more efficient? Do these usually come with covers? The galvanized duct in the picture is your cold air return. The filter is to catch particles before they enter the furnace and are returned to the living area. The furnace is pulling some air from the area where the furnace is located, which means it's not pulling as much from the living area. I would make up a cover from a piece of galvanized steel or other material and seal the opening. It does. of course, need to be removable to change filter. Thanks, I thought I might need a cover. I was also wondering about which way the filter should go in too. So in the picture the air is traveling left to right through the filter - right? Sometimes the sheet metal is formed into a slot so that the sheet metal cover that ought to go in there can be slid into place. Other times there is an S cleat that allows a sheet metal cover to be pushed into place in the cleat, sealing the opening. Which do you have? jughead47 Thanks, I thought I might need a cover. I was also wondering about which way the filter should go in too. So in the picture the air is traveling left to right through the filter - right? Right. The arrow on the filter should point towards the furnace.
Related Posts:
Century bryant or concord furnace 2stage vs variable speed
Century, Bryant or Concord Furnace 2-stage vs variable speedHello everyone. I am pricing a new furnace for a 2832 sq ft house. It was built in 2008. The furnace was damaged in a flood prior to my...
Bryant 90 plus furnace wont stay lit
Bryant 90 Plus furnace won't stay litLet me back up some here. Last week furnace started acting up but it was only on for short periods because the weather was nice. This last weekend furnace woul...
Bryant gas furnace wont ingnite
Bryant Gas furnace won't ingniteI have a Bryant Plus 90 gas furnace. When themostat calls for heat it will sometimes blow cold air, or will shut itself down. The LED is giving a code 21 which the...
Bryant plus 90i model 355mav042080ffk gas furnace no light is on
Bryant Plus 90i Model 355MAV042080FFK Gas Furnace - no light is onWe have had our furnace serviced annually since it's installation 9 years ago. It was recently serviced 9/21/11. We were given the...
Carrier furnace limit switch is tripping
Carrier Furnace Limit Switch is TrippingI have Carrier Furnace model 58PAV111-20 The limit switch keeps trips after running for about 5 minutes. I can reset the switch but it trips. I looked on li...